<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-03 12-08-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 15 kHz 17370 2,0956
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 3,20 dBr 4,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 15 kHz MIN: 9 kHz % above 76 kHz: 2,0956 Acquired: 2025/05/03 12.07.51 Total samples: 17370 Equivalent time: 0:14:28 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,3 dBr MIN: 2,3 dBr AVE: 3,20 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2025/05/03 12.07.50) 11.54 11.56 11.58 12.00 12.02 12.04 12.06 0 2 4 Pm [dBr]